VXA-210 PILOT OPERATING MANUAL
23
BAROMETRIC PRESSURE/ALTITUDE METERING
Correcting the Atmospheric Pressure Meter
(Barometer Offset)
r Press the
[
F
]
key, then press the DIAL selector
knob to activate the Menu (“SET”) mode.
r Rotate the DIAL selector knob to select Menu
Item 15 “BARO.”
r Press the DIAL selector knob to enable adjust-
ment of this Menu item.
r Rotate the DIAL selector knob to set the differ-
ence (value: in hpa) between the VXA-210 dis-
play and the calibrated barometer display. For
example, if the VXA-210 display shows “1024
hPA” and calibrated barometer indicates “1029
hpa,” set the Barometer offset to “+005”.
r Press the DIAL selector knob to save the new
setting, and then press the PTT key exit to nor-
mal operation.
Correcting the Altimeter Setting
(Altimeter Offset)
r Press
[
F
]
à
[
5
(
ALT.SET
)]
to enable the Altim-
eter Set function.
r Enter the proper local barometric pressure value
(in “HG”) of the airport directry from the key-
pad. For example, if the current Barometric Pres-
sure at the airport is “30.05 HG,” press
[
3
]
à
[
0
]
à
[
0
]
à
[
5
]
on the keypad.
r Press the PTT key to save the new setting and
exit to normal operation.
When the Altimeter function is brought up (by press-
ing
[
F
]
à
[
6
(
SENSR
)]
), the VXA-210 will now
display your correct altitude (+/
tolerance of the SU-
1). Please remember that the Altitude function of the
VXA-210 is not intended to serve as your primary
altimeter instrument.
Once you have completed the above calibrations, you
can confirm the current Temperature, Barometric
Pressure, Altitude, or Density Altitude.